Application - Pipelines
Bronya thermal insulation coatings are easily applied to pipelines and are simple to maintain!
Application of Bronya thermal insulation coatings on pipelines (steam pipes, oil pipelines, gas pipelines, etc.)
Liquid ceramic thermal insulation is a high-performance material for the thermal insulation of external and internal walls, roofs, door frames, window frames, concrete floors, hot and cold water pipes, steam pipes, ventilation and air conditioning pipes, refrigeration systems, various tanks, containers and tanks, trailers, refrigerated trucks, etc. It is applied to prevent condensation on cold water pipelines and to prevent heat loss in heating systems.
Reduces heat loss by 6-8 times!
All material properties have been confirmed!
Simple material sustainability!
All products are certified!
10-year lifespan
Effective external and internal thermal insulation
Protective coatings have found extensive application on main and internal pipelines. The application of thermal insulation coatings achieves a reduction in heat loss by 6–8 times without the need for a protective layer, thus replacing conventional insulating materials such as glass and mineral wool, pipe insulation, polyurethane foam, and the like.
It is important to note that Bronya coatings are easily maintained and do not lose their properties during their lifespan. When refreshing, it is not necessary to remove the old coating; simply apply a new layer, which completely restores the thermal insulation properties.
Bronya thermal insulation coatings are ideal for external use (thermal insulation of heating pipes) and internal use (insulation of pipelines in boiler rooms, heating and pump stations, etc.).
Bronya ultra-thin thermal insulation coatings can maintain the temperature inside pipelines that require constant low temperatures of fluids, such as liquefied gases.
Thermal insulation of equipment and pipelines effectively protects them from the harmful effects of ultraviolet radiation, improves corrosion protection, and can be painted according to client wishes. It is very sustainable, and the coating helps reduce insulation loss during planned inspections (repair work) or in case of pipeline leaks.
Recommended Bronya Products
For thermal insulation and anti-corrosion protection on pipelines

Bronya Anticor
It is applied directly to the pipe surface as first layer which acts as a primer for other Bronya coatings

Bronya Classic
It is applied in one or more layers on top of primer and it acts as a thermal barrier.
Application of Bronya products
Reducing the surface temperature on metal pipes (Ø 150 mm)
| Bronze coating thickness in mm | Surface temperature in °C | |||||
|---|---|---|---|---|---|---|
| 0 | 60 | 80 | 100 | 120 | 150 | 200 |
| 1 | 42 | 54 | 64 | 68 | 77 | 100 |
| 1,5 | 33 | 42 | 56 | 57 | 64 | 75 |
| 2 | 31 | 35 | 45 | 51 | 58 | 70 |
| 2,5 | 30 | 31 | 42 | 46 | 50 | 66 |
| 3 | 28 | 29 | 35 | 42 | 45 | 52 |
| 4 | 25 | 26 | 32 | 35 | 39 | 45 |
Reduction of heat loss in district heating pipelines
Approximate calculation of the thickness of Bronya liquid ceramic thermal insulation on hot water and heating pipes
| Prosječna temperatura površine °C | Calculated Bronya coating thickness mm | Rounded Bronya coating layer thickness in mm | Approximate consumption when applying with a brush in liters/m2 |
|---|---|---|---|
| 0-40 | 0,46 | 1 | 1,1 |
| 40/45-80-85 | 1,04 | 1 | 1,1 |
| 80/85-100/110 | 1,56 | 1,5 | 1,65 |
| 100/110-160/180 | 1,97 | 2 | 2,2 |
| 160/180-200/210 | 2,79 | 3 | 3,3 |
| 200/210-260 | 3,92 | 4 | 4,4 |